Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the wp-parsidate domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/modjenir/public_html/wp-includes/functions.php on line 6260

Notice: Function _load_textdomain_just_in_time was called incorrectly. بارگذاری ترجمه برای دامنه flatsome-admin زودتر از حد مجاز فراخوانی شد. این معمولاً نشان‌دهندهٔ اجرای کدی در افزونه یا پوسته است که خیلی زود اجرا شده است. ترجمه‌ها باید در عملیات init یا بعد از آن بارگذاری شوند. Please see Debugging in WordPress for more information. (این پیام در نگارش 6.7.0 افزوده شده است.) in /home/modjenir/public_html/wp-includes/functions.php on line 6260
Providing a practical solution to improve the automation system of distribution posts with the criterion of increasing reliability – شرکت موج نیرو

Providing a practical solution to improve the automation system of distribution posts with the criterion of increasing reliability

In recent decades, the use of automation systems in the field of electricity industry and especially at the level of distribution has received significant attention. In the meantime, the importance of modernizing the automation of distribution substations as an important link in Iran’s electricity network is felt more than in the past. Due to the vastness of the provinces of our country, the distribution posts are widely scattered in the geographical area. On the other hand, the radial structure of distribution systems has made its accessibility more difficult compared to production and transmission systems.

Therefore, a plan to increase reliability with a local visibility approach is felt in order to troubleshoot and check the accuracy of information with easy access and use for the employees of these posts. For this purpose, in this article, a plan is presented using remote terminals for distribution systems with a combination of DNP3 and Modbus RTU protocols. This plan reduces the average number of system outages (SAIFI) and the average outage time (SAIDI). This method has been tested and applied on a trial basis in one of the distribution posts of Mashhad, which is one of the vast provinces of Iran.