Transducers
- List of Transducers Contents
- Active and Reactive Power Transducer
- Voltage Transducer
- Current Transducer
- Resistor (Tap Position) Transducer
- MPR-G3
Active and Reactive Power Transducer
Input-Output
Nom. Input Voltage (ph. to ph.)(Vn) | 100V, 110V, 120V |
Nominal Input Current (In) | 1A, 5A |
Output Current Range (Iomin-Iomax) | 0-1, 5, 10,20mA, 4-20mA, -2.5 to +2.5 mA |
Rated Frequency | 45Hz - 55Hz (50Hz for Reactive Power Transducer) |
Overload Continues (Voltage) | 1.2Vn |
Overload for 10 Seconds (Voltage) | 1.5Vn |
Overload Continues (Current) | 1.5In |
Overload for 1 Seconds (Current) | 20In |
Power Consumption | <5VA |
Maximum Current Burden | <0.5VA |
Maximum Voltage Burden | <2VA for each line (Self Powered) |
<0.1VA (Auxiliary powered) | |
Output Open Circuit Voltage | <20V |
Maximum Load | 10V / Iomax |
Max input for Max output | 1.2√3VnIn |
Accuracy
Class of Accuracy | ±0.5% |
Output Ripple | < 0.5% |
Range of Valid Accuracy | 20% to 120% of Nominal input |
0% to 120% of Nominal input (Auxiliary powered) |
General
Case | Polycarbonate |
Fire | Inflammable |
Fixing | Rail and Panel |
Size | 90*90*136 (mm) |
Working Temperature | 0 to 55°C |
Storage Temperature | -15 to 60°C |
Response Time | <300mSec |
Isolation | 2KV for 1 min. |
Protection Degree | IP-30 |
Standard Compliance
General IEC-688
Safety IEC-414, IEC-529
Auxiliary Supply
AC | 100-120 Vac,±20% |
DC | 48 Vdc±20% |

Active and Reactive Power Transducer
Voltage Transducer
Input-Output
Nom. Input Voltage (ph. to ph.)(Vn) | 100V, 110V, 120V |
Nom. Input Voltage (ph. to N)(Vn) | 100/√3,110/√3,120/√3 |
Output Current Range (Iomin-Iomax) | 0-1, 5, 10, 20mA, 4-20mA |
Rated Frequency | 45Hz - 55Hz |
Overload Continues | 1.2Vn |
Overload for 10 Seconds | 1.5Vn |
Power Consumption | <1.5VA |
Maximum Burden | <1.5VA (Self Powered) |
<0.1VA (Auxiliary Supplied) | |
Output Open Circuit Voltage | <20V |
Maximum Load | 10V / Iomax |
Max input for Max output | 1.2Vn |
Accuracy
Class of Accuracy | ±0.2% |
Output Ripple | < 0.2% |
Range of Valid Accuracy | 20% to 120% of Nominal input |
0% to 120% of Nominal input (Auxiliary powered) |
General
Case | Polycarbonate |
Fire | Inflammable |
Fixing | Rail and Panel |
Size | 96*60*114 and 90*90*130 (mm) |
Working Temperature | 0 to 55°C |
Storage Temperature | -15 to 60°C |
Response Time | <300mSec |
Isolation | 2KV for 1 min. |
Protect Degree | IP-30 |
Standard Compliance
General IEC-688
Safety IEC-414, IEC-529
Auxiliary Supply
AC | 100-120 Vac,±20% |
DC | 48 Vdc±20% |

Voltage Transducer
Current Transducer
Input-Output
Nominal Input Current (In) | 1A, 5A |
Output Current Range (Iomin-Iomax) | 0-1, 5, 10, 20mA, 4-20mA |
Rated Frequency | 45Hz - 55Hz |
Overload Continues | 1.5In |
Overload for 1 Seconds | 20In |
Power Consumption | <2VA |
Maximum Burden | <2VA (Self Powered) |
<0.5VA (Auxiliary Supplied) | |
Max. Output Voltage | <20V |
Maximum Load | 10V / Iomax |
Max input for Max output | 1.2In |
Accuracy
Class of Accuracy | ±0.2% |
Output Ripple | < 0.2% |
Range of Valid Accuracy | 10% to 120% of Nominal input |
0% to 120% of Nominal input (Auxiliary powered) |
General
Case | Polycarbonate |
Heat | inflammable |
Fixing | Rail and Panel |
Size | 96*60*114 and 90*90*130 (mm) |
Working Temperature | 0 to 55°C |
Storage Temperature | -15 to 60°C |
Isolation | 2KV for 1 min. |
Protection Degree | IP-30 |
Standard Compliance
General IEC-688
Safety IEC-414, IEC529
Auxiliary Supply
AC | 100-120 Vac,±20% |
DC | 48 Vdc±20% |

Current Transducer
Resistor (Tap Position) Transducer
Input-Output
Nom. Input Resistance | According to Order |
Output Current Range | (Iomin-Iomax) 4-20mA |
Output Open Circuit Voltage | <20V |
Maximum Load | 12V / Iomax |
Accuracy
Class of Accuracy | ±0.2% |
Output Ripple | <0.2% |
General
Case | Polycarbonate |
Fixing | Rail and Panel |
Size | 96*60*114 and 90*90*130 (mm) |
Working Temperature | 0 to 55°C |
Storage Temperature | -15 to 60°C |
Response Time | <300mSec |
Isolation | 2KV for 1 min. |
Protection Degree | IP-30 |
Standard Compliance
General IEC-688
Safety IEC-414, IEC-529
Auxiliary Supply
AC | 100-120 Vac,±20% |
DC | 48 Vdc±20% |

Resistor (Tap Position) Transducer
MPR-G3
Paperless recorder
GENERAL SPECIFICATION:
- Input signal: 4-20 mA
- Number of channels: 6
- Horizontal vertical bar & graph single channel & all channel display
- Digital output and alarming capability
- Channel to channel and bus isolation
- Communication standard: IEC
- Easy available & upgradeable
- Daylight saving
- Software based on industrial reliable multitask real time platforms
- At least 0.3% accuracy of measurement
- Natural cooling
- Long life industrial LCD
- More than one month storage capacity
- Wide range power supply: 18-36 VDC
- Menu driven user interface
- Support of standard USB flash for data transfer & storage
- Wide viewing angle
- Self programming
- Online history analyzing
- Powerful analyzing tools
- Direct excel file output
- Setting based on password
- Online system setting (no data lost)
- Modular hardware setting
- Hot plug in and out input modules
- Self diagnosis & self checking